| Input |
Voltage |
120VAC-277VAC |
| Frequency Range(Hz) |
50/60Hz |
| Efficiency |
≥88%@120VAC, ≥89%@230VAC, ≥90%@277VAC, full load |
| PF |
≥0.95@120V-277VAC,full load |
| Current |
0.72A max@120VAC, 0.35A max@230VAC, 0.28A max@277VAC, full load |
| THD |
<10%@120-277VAC, full load |
| Inrush current |
Cold start, 18A@120VAC 200us, 36A@230VAC 200us, 46A@277VAC 210us, |
| No load power |
<0.5W |
| Turn on Time |
≤0.5s, at120-277Vac (When the light begins to shine) |
| Output |
Voltage |
24VDC |
| Voltage Accuracy |
±3% |
| Output Current |
2.5A |
| Power |
60W |
| Channel |
1 |
| Ripple Voltage |
≤240mV(p-p) |
| Protection |
Overload |
Hiccup Protection, Auto-recovery after Fault Clearance |
| Short circuit |
No Output, Auto-recovery after Fault Clearance |
| Overcurrent |
Hiccup Protection, Auto-recovery after Fault Clearance |
| Over temperature |
Output power drops to 50% at 75-80°C ambient (Tc ≈95°C-100°C ), recovering automatically when temperature normalizes. |
| Safety&EMC |
Surge |
L-N 6kV L/N-G 6kV |
| Withstand Voltage |
I/P-O/P:3000Vac/1min/<5mA |
| Safety standards |
EN61347-1, EN61347-2-13; UL8750:2015 Ed.2+R:07Dec2022, UL1310, CSA-C22.2 No. 250.13:2022 Ed.5 |
| EMI Emission |
EN55015, EN61000-3-2 Class C,IEC61000-3-3; FCC Part 15 Class B(120V)/Class A(277V) |
| EMS lmmunity |
EN61547, EN61000-4-2, 3, 4, 5, 6, 8, 11 |
| Insulation Resisance |
5MΩ |
| Others |
Working temp. |
ta:-40…+60℃(-40°F~140°F) |
| tc |
90℃(194°F) for safety & life |
| Storage Temp Humidity |
-40℃~85℃(-40°F~185°F), 20-90%RH |
| Lifetime |
50,000h@tc:90℃(194°F) |
| Warranty |
5 years |
| IP rating |
IP65 |
| Material |
Metallic |
| Switch cycle |
>25000 times |
| Dimension |
244*106*41.5mm (9.61*4.17*1.63 Inch)(L*W*H) |
| Packing size |
Net weight: TBDg (– lb)±5%/PCS; 12PCS/Carton;–kg(– lb)±5%/Carton; Carton Size: 314*263*249mm(12.36*10.35*9.8 Inch)(L*W*H) |